Cochlear Implant Integrity Maintained Following Electrosurgery to Remove Adenoids on Animal Model

Children's HealthMay 19, 06

Cochlear implant device intergrity is not compromised by electrosurgery used in removal of tonsils and adenoids. This finding from a new experiment could be an important first step to providing safe, effective, and the most pain-free removal of tonsils and adenoids for deaf children.

Cochlear implant (CI) recipients have been discouraged from having monopolar electrosurgery for ear, nose, and throat procedures due to concerns over possible damage to the implant and the auditory neurons. While monopolar electrosurgery is rarely, if ever, absolutely necessary, it greatly facilitates treatment in certain procedures such as adenoidectomy. With a growing population of patients receiving CIs at very young ages, more children with CIs may subsequently develop a need for an adenoidectomy, such as obstructive sleep apnea. Unfortunately, no published studies have evaluated the safety of electrosurgical adenoidectomy in CI reipients.

Over the past few years, radiofrequency bipolar electrosurgery (eg, Coblation™) has become popular for adenoidectomy and tonisillectomy because of reports of less post-tonsillectomy pain. The reduction in post-tonsillectomy pain has been attributed to the more limited spread of electrical current and reduced tissue temperatures with Coblation bipolar electrosurgery relative to monopolar electrosurgery.

The more limited current spread with Coblation electrosurgery would theoretically impart less risk to a CI and the auditory neurons. As with other electrosurgical techniques, no studies have reported the safety of Coblation adenoidectomy in CI recipients.

A new study evaluates the possible impact of adenoidectomy with monopolar electrosurgery and Coblation electrosurgery on the integrity of CIs using a cadaveric animal model. The authors of “Cochlear Implant Integrity Following Adenoidectomy with CoblationTM and Monopolar Electrosurgery,” are Patrick J. Antonelli MD, from the Department of Otolaryngology, University of Florida, Gainesville, FL, and Roxana Baratelli MD, at the Department of Otolaryngology, Tulane University, New Orleans, LA. Their findings will be presented at the Annual Meeting of the American Neurotology Society being held May 20-21, 2006, at the Hyatt-Regency Hotel, Chicago, IL.

Methodology: Twelve frozen 40 -  50 pound pigs and 12 cochlear implants with superficial defects were used for the experiment. After thawing the pigs, the cochlear implants were placed unilaterally via a standard transmastoid approach. Saline was infiltrated into the cochlea and middle ear to ensure contact between the electrode and surrounding tissues, then the wound was closed with running locked silk suture.

Nasopharyngeal Electrosurgery: The palate and posterior wall of the nasopharynx were treated with either monopolar electrocoagulation or Coblation bipolar electrosurgery. Both were applied with continuous saline irrigation to ensure maximum electrical conduction. The monopolar cautery unit was set at 50, which is double the energy level typically used for adenoidectomy at our institution, and applied for 15 minutes; radiofrequency bipolar electrosurgery was performed using the Coblator II system. The duration of Coblation treatment was doubled to 30 minutes because of the inability to double the intensity of treatment beyond its maximum level of 9, as was done with the monopolar electrosurgical treatment. This yielded a total of 270 J with Coblation treatment.

Cochlear Implant Integrity Assessment: Implants underwent standard integrity checks by the manufacturer prior to shipping and after electrosurgery. These evaluations included open circuits, device electronics, ability of the device to function at normal levels, and stability of stimulation delivered by each channel. The manufacturers were blinded to the treatment group. Immediately prior to and after subjecting the animals to electrosurgery, “clinical” telemetry was performed on each device by the respective manufacturer’s technical staff to ensure proper functioning of the device in situ.

Results: Intraoperative telemetry revealed normal impedances and device integrity in all of the cochlear implants with the exception of the fifth Nucleus 24 CI, treated with electrocautery, which demonstrated an open electrode #15, both pre and post electrosurgery. Manufacturer testing revealed no additional abnormalities in any of the cochlear implants exposed to either monopolar or Coblation electrosurgery.

Conclusions: The study findings were intended to evaluate the cochlear implant device integrity, not support the safety of monopolar or Coblation electrosurgery in respect to the patient. The study also did not evaluate the effects of either treatment modality on auditory neurons. Further evaluation of adenoid electrosurgery would require evaluation of electrically evoked auditory brainstem response testing in a long-term animal model, and ultimately in human CI recipients.

The researchers believe that their observations should be viewed as merely a first step toward establishing the safety of various electrosurgical technologies for head and neck procedures, such as adenoidectomy, and they should be recognized as not being necessarily directly reflective of the human condition. They suggest that in the absence of definitive high level evidence (i.e., controlled trials) to guide treatment decisions, lower level evidence must be used to guide treatment. On a theoretical level, Coblation should be safer than monopolar electrosurgery, because the former involves bipolar current passing through tightly approximated electrodes on the end of the electrosurgical wand, whereas monopolar current may spread in a much more diffuse pattern from the nasopharynx to the grounding pad. Unlike other forms of electrosurgery, there are no reports on the safety of Coblation electrosurgery with other implantable stimulators, such as pacemakers and cardiac defibrillators.

American Neurotology Society



Print Version
Tell-a-Friend
comments powered by Disqus

RELATED ARTICLES:
  UTSW researchers identify a therapeutic strategy that may treat a childhood neurological disorder
  Siblings of children with autism can show signs at 18 months
  Study finds hazardous flame retardants in preschools
  ADHD drugs not linked to increased stroke risk among children
  Online alcohol marketing easily accessed by kids
  Brain chemical ratios help predict developmental delays in preterm infants
  Common genetic pathway could be conduit to pediatric tumor treatment
  Think twice before buying breast milk online: study
  Child Abuse Ad Shows Hidden Message for Children
  90 percent of pediatric specialists not following clinical guidelines when treating preschoolers with ADHD
  Limited impact on child abuse from visits, intervention: study
  Breathing program may held save newborns’ lives: studies

 












Home | About Us | FAQ | Contact | Advertising Policy | Privacy Policy | Bookmark Site